Steel Columns Design Problem 1 - Design a steel column:
|
Design a steel W12 column using ASD for a load of 637.5 kips.
The column is 50 feet long with pinned ends (rotation permitted, translation prevented).
The weak axis of the column is laterally braced at midheight.
|
|
1. From the steel columns submenu open the compressive strength for flexural buckling of non-slender sections calculation, NSFBCompStrength.aspx.
Input the "Title" of the calculation, the "Designer/Checker" information.
Then from the steel shape section properties submenu open the W section properties table, WShapeTables.pdf.
Starting with a W12 x 136 section, enter the variables click on the "Calculate" button and read the results. The capacity is 614.994 kips which is less than 637.5 kips.
|
|
2. Next, try a W12 x 152 section. Enter the variables click on the "Calculate" button and read the results. The capacity is 701.939 kips which is greater than 637.5 kips.
|
|
3. Next determine KLy. Using rx/ry = 1.77, KLy = 50/1.77 = 28.25.
Try a W12 x 170 section. Enter the variables click on the "Calculate" button and read the results. The capacity is 671.836 kips which is greater than 637.5 kips.
|
|
4. Summary
|
The lightest W12 section is a W12 x 170, with a capacity of 671.836 kips.
|
|