Structural Wood Design Problem 2 - Design a Wood or Timber Column:

What is the ASD axial load capacity of a solid sawn no. 2 Hem-Fir 6x6 column?
Actual Dimensions are 5.5"x5.5", it has pinned-pinned ends, length is 14 ft.
Moisture condition is 22% and the surroundings are at room temperature.

1.
From the structural wood submenu open the Other North American Species Wood Reference Tables, Wood_Reference_Design_Values.pdf.
Derive all the factors and properties for a sawn no. 2 Hem-Fir 6x6 column.













2.
Next, from the structural wood submenu open the column stability factor calculation, ColumnStabilityCp.aspx. Input the "Title" of the calculation, the "Designer/Checker" information, enter the variables, click on the "Calculate" button and read the results.
Use Cp = 0.317.








3.
From the structural wood submenu open the wood compression calculation, WoodCompression.aspx. Input the "Title" of the calculation, the "Designer/Checker" information, enter the variables, click on the "Calculate" button and read the results.
The ASD axial strength of the column in compression is 11,468.74 lbs.








4. Summary
The ASD axial strength of the column in compression is 11,468.74 lbs.


 




Start Using The Calculations >>> Become A Member Now!